Skip to main content

HIV Screen - HIV Ag-Ab Multiplex

Laboratory Fee Schedule
Procedure: MBP0229A 
CPT: 87389, 86701, 86702, 87390

Synonym(s): HIV Antigen/Antibody, HIV-1, HIV-2, p24 antigen, Human Immunodeficiency Virus, HIV-1/-2 Ag-Ab
Requisition Form G-2A
Test Description The BioPlex 2200 HIV Ag-Ab assay is a multiplex flow immunoassay that is run on the fully automated BioPlex 2200 system. The assay methodology permits simultaneous detection and identification of anti-HIV-1, anti-HIV-2, and HIV-1 p24 antigen in a single reaction vessel. 
Pre-Approval Needed N/A
Supplemental Information Required N/A
Supplemental Form(s) N/A
Performed on Specimens from (sources) Human
Sample/Specimen Type for Testing Serum collected in serum separator tube (SST) or red top tubes
Minimum Volume/Size Required 1.0 mL
Storage/Preservation Prior to Shipping
  • Store at 2°C to 8°C for up to 5 days.
  • Store frozen at -20°C or colder for long term storage.
Transport Medium N/A
Specimen Labeling
  • Two patient-specific identifiers required on specimen (e.g., patient full name, date of birth, medical record number) 
  • Three patient identifiers are preferred. 
  • Patient identifiers on specimen label must exactly match identifiers on submission form (e.g., abbreviated name on label and full name on form is not acceptable.)  
  • Additional DSHS Laboratory specimen labeling guidelines available online here. 
Shipping and Specimen Handling Requirements
  • Ship according to Dangerous Goods Regulations, IATA, and/or CFR 49. 
  • Category B Biological Substance, UN3373 shipping requirements apply.  
  • Handle as infectious agent using universal precautions.  
  • Triple contain in accordance with federal shipping regulations for infectious agents.  
  • Submitters are responsible for packaging and shipping specimens according to regulatory requirements.  
  • If specimens will arrive at the Lab within 5 days of collection, refrigerate at 2°C –8°C and ship overnight on cold packs. 
  • If specimens will arrive at the Lab more than 5 days after date of collection, freeze at -20°C or below, and ship overnight on dry ice. 
  • Additional DSHS Laboratory specimen shipping guidelines online here.
Method Multiplex Flow Immunoassay
Turn-around Time 4 working days
Interferences/Limitations Contaminated, icteric, lipemic, hemolyzed or heat inactivated sera may cause erroneous results and should be avoided. 
Common Causes for Rejection
  • Insufficient specimen quantity.
  • Unacceptable specimen type or source.
  • Improper shipping conditions.
  • Expired media or collection container.
  • Expired reagents/media/collection container. 
  • Discrepancies between G-2A submission form and specimen label. 
  • Missing/incomplete/illegible submission form or label.
Additional Information
  • This assay should not be used on individuals younger than 2 years of age.  
  • Non-reactive results do not preclude the possibility of exposure to or infection with HIV-1 and/or HIV-2 
  • Reactive specimens will automatically reflex to HIV Confirmation testing per the CDC algorithm.